. . If it does not fire at first, push the OFF switch, wait five minutes, and again push the POOL or SPA ON switch. . . Pentair Mastertemp 250 Diagnosis problem. Improper installation and/or operation could create carbon monoxide gas and flue gases which could cause serious injury or death. . The air flow switch (AFS) senses the pressure drop across the air metering orifice. . The heater, when installed, must be electrically grounded and bonded in accordance with local codes, or, in absence of local codes, with the Canadian Electrical Code or the National Electrical Code, ANSI/NFPA70, as applicable. . Follow drain manufacturer’s installation instructions. This is an no question easy means to specifically get guide by on-line. . Fasten the metal Flue Collar to the Vent Body with two #10 sheet metal screws. Do not try to light the burner by hand. POOL AND SPA HEATER 120/240 VAC NATURAL GAS/LP GAS. . . Keep the area in and around the heater clear and free from combustible materials, gasoline and other flammable vapors and corrosive liquids. . . This manual supplies information for the installation, operation, and servicing of the appliance. . Slope horizontal pipe runs up from the heater at least 1/4" per foot (2cm per meter). Model 300. 3.Turn off all electric power to the appliance. Close main gas control valve and manual gas valve (located outside the heater). . Instead, follow instructions under “To Switch Off Gas to the Appliance,” and call a qualified service technician to repair unit. . . Pentair/Sta-Rite 77707-0054 Igniter & Gasket Kit HTR . Do not install the heater using propane in pits or other locations where gas might collect. Pentair MasterTemp Heater Parts At Parts4Heating.com we carry a wide selection of MasterTemp pool heater replacement parts for Pentair MasterTemp 175 - 400 series heaters. Pentair MasterTemp HD Low NOx Pool Heater - Electronic Ignition - Cupro Nickel - Natural Gas - 250,000 BTU HD - 460806 $ 2,091.55 . The Pentair 460737 MasterTemp Eco-Friendly Heater is a 400K BTU high performance propane gas pool heater. Minimum 1 and maximum 5 tags. •the automatic gas shutoff (AGS) switch, which opens if the heat exchanger outlet temperature goes above 140° F (60° C). If the heater is under a roof or deck overhang, the space around the heater must be open on three sides. . . 2.Set both pool and spa thermostats to the lowest settings. . WARNING Risk of explosion if unit is installed near propane gas storage. User Manuals, Guides and Specifications for your Pentair MASTERTEMP 200 HD Swimming Pool Heater. MasterTemp Pool and Spa Heater Installation and User’s Guide 1 1 Pentair Water Pool and Spa, Inc. USA – 1620 Hawkins Ave., Sanford, NC 27330, USA • (919) 566-8000 • (800) 831-7133 – INSTALLATION AND USER’S GUIDE MASTERTEMP™ 125 POOL AND SPA EURO DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity Only 1 left in stock - order soon. . . . – any latin characters (a-z, A-Z)– any numbers (0-9)– special characters ("-", "_" and "."). . If you then smell gas, STOP! . Pentair Mastertemp 250 Manual File Type Author: s2.kora.com-2020-11-09T00:00:00+00:01 Subject: Pentair Mastertemp 250 Manual File Type Keywords: pentair, mastertemp, 250, manual, file, type Created Date: 11/9/2020 3:16:07 AM . If this light is on but the burner fails to come on, one of the “service” lights should come on, indicating a fault in the system. Leave 3 ft. (1 M) or more of clearance above heater, Leave 6 in. Table 3: Permitted Minimum and Maximum Vent Heights By Size and Heater Model. Do not operate the pool heater unless the pool or spa is properly filled with water. As understood, exploit does not suggest that you have fabulous points. Used On Pentair Mastertemp® Heaters Used On Pentair Mastertemp 125 Heaters Used On Sta-Rite Max-E-Therm Heaters This 6 pin board replaces the now obsolete 42001-0096S which was a 9 pin board. WARNING Risk of explosion or fire causing burns or death if safety interlocks are disabled. Pipe support must allow the vent pipe free movement out and back, from side to side, or up and down as necessary, without putting a strain on the heater or vent body. This heater is design certified by CSA International as complying with the Standard for Gas Fired Pool Heaters, ANSI Z21.56/CSA 4.7, and is intended for use in heating fresh water swimming pools or spas. ... Model 250. Damage to equipment caused by improper installation or repair will void the warranty. . . Horizontal vent runs must slope up 1/4" per foot (2cm/M) from the heater to allow exhaust condensate to drain and must have a condensate drain as described in the venting installation instructions. Improper installation and/or operation will void the warranty. User Manuals, Guides and Specifications for your Pentair MASTERTEMP 300K BTU/HR Swimming Pool Heater. In extreme weather, shut down the heater and disconnect the power to it until the weather has moderated. . DO NOT attempt to operate heater when SERVICE HEATER light is on or if blower or burner will not start. For pools used only on weekends, lower the thermostat setting by 10° F to 15° F (5° C to 8° C) during the week to reduce heat loss. . . . . The burner does not require maintenance or adjustment by the user. . With a hot surface ignition (no pilot light) and pushbutton, digital controls, the MasterTemp heater is … . See also “BEFORE STARTUP” (Page 4) and “CARE AND MAINTENANCE” (above). . . . WARNING Risk of asphyxiation if exhaust is not correctly vented. Refer to the nameplate for the type of gas the heater is equipped to use. MANUAL COMPLETELY before proceeding with an installation. . Pool Heaters Pentair MasterTemp HTR 250. Sta-Rite 42001-0063S Hi-Limit Switch . Do not use this heater if any part has been under water. Locate the heater on a level surface in an open area that is protected from drainage or run-off. When operating for the first time or after an extended. See Figure 8 for minimum clearances. Replace the top panel down onto the side panels. . . Owners Manual . You may have to repeat this until all of the air has cleared the gas line. . If you cannot change the ON/OFF setting by hand, don’t try to repair it, call a qualified service technician. . If the heater is installed in a closet or alcove, the entire floor shall be covered by the panel. Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subsequently result in drowning. 18, Checking Combination Gas Control Valve . . Eco-friendly, the MasterTemp gas heater is certified for low NOx emissions and outperforms industry standards. Pentair Mastertemp 250 Manual View and Download Pentair Pool Products MASTERTEMP 250K BTU/HR installation and user manual online. . . The combustion air blower is permanently lubricated, and does not require periodic lubrication. WARNING Risk of fire and explosion if installed at floor level in an automotive garage or near gasoline or flammable liquid storage. 4, Owner’s Operating Instructions . WARNING Risk of fire or explosion from flammable vapors. . . or explosion may result causing property damage, personal injury or death. . . . The control panel located on the top panel can be rotated to any of the three sides of the heater for easy access. . . In the U.S. and Canada: The heater is certified for installation on combustible flooring. FIGURE 6: Operating Control for all models. If the light remains on after the filter/skimmers have been serviced, the system should be checked by a qualified service technician. 4.Remove the Water Pressure Switch. ... Model 250. . View and Download Pentair MASTERTEMP 250K BTU-HR instruction manual online. . (15cm) of clear space between heater and combustible surface, FIGURE 10: Minimum outdoor shelter clearances (Canada) or minimum garage or utility room clearances (U.S.). . Pentair Mastertemp 250 Manual Free Books PDF Pentair Mastertemp 250 Manual Free Books PDF Books this is the book you are looking for, from the many other titlesof Pentair Mastertemp 250 Manual Free Books PDF books, here is alsoavailable other sources of this Manual MetcalUser Guide Seidel Smokin Token Owners Manual PDF Full Ebook Never use tools. . . Provide an adequate ventilation air supply (See Table 2, Page 11). All panels must be in place when operating the heater. . Do not allow children to play on or around heater or associated equipment. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. . BEFORE OPERATING check for odor. MasterTemp heaters are engineered for super-quiet operation and wonât intrude on your poolside leisure time. Pentair Mastertemp 250 Manual Author: media.ctsnet.org-Anna Gerber-2020-11-25-17-57-43 Subject: Pentair Mastertemp 250 Manual Keywords: pentair,mastertemp,250,manual Created Date: 11/25/2020 5:57:43 PM Be sure that there are no wires caught under the panel. Soaking in water above 102° F (39° C) can cause fetal damage during the first three months of pregnancy (resulting in the birth of a. Do not attempt to adjust the gas flow by adjusting the regulator setting. A tough, rustproof composite exterior handles the heat and weathers the elements. WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Support the vent pipe according to applicable codes and the vent manufacturer’s instructions. Remove both door panels. . . . A properly sized heater will restore normal temperature within one day. Only qualified service technicians should attempt to service the heater, as leakage of exhaust products or flammable gas may result from incorrect servicing. NOTICE: Water trapped in the heater can cause freeze damage. It is equipped with an ignition device which automatically lights the burner. Locate the heater away from propane gas storage and filling equipment as specified by the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58 (latest edition). Make sure that the filter is not plugged. . Optimum Pool Technologies Heater Repair Kit for Pentair MasterTemp & Max-E-Therm - Replacement Thermistors & Switches. Persons with medical history of heart disease, circulatory problems, diabetes or blood pressure problems should obtain their physician’s advice before using spas or hot tubs. Our digital library hosts in multiple locations, allowing you to get the most less latency time to download any of our books like this one. 2.Keep heater area clear and free from combustibles, flammable liquids and chemicals. Orient the heater for convenient access to the water connections and the gas and electrical connections. To maintain pool temperature, make sure that the heater switch and valving are reset to pool settings after using the spa. Read Online Pentair 250 Pool Heater Manual Pentair 250 Pool Heater Manual Getting the books pentair 250 pool heater manual now is not type of inspiring means. . Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile flammable liquids near heater or in the same room with heater. A properly sized heater will restore normal temperature within one day. . . Pentair Mastertemp 300 won't fire, LED 11 only one lit. . . 5.Replace the top panel down onto the side panels. Sure the ventilation openings are clear of debris or obstruction gas is installed in an automotive garage near! Room that is factory set with a plastic bag to prevent bugs, leaves, etc., getting. Experienced installers only above Ground pools... Sta-Rite ( Pentair ) 42001-0052S: $ 49.82: Order... For your area swimming pools or spas only that secure the top panel down onto the side panels reduce... Manual completely before proceeding with an ignition device which automatically lights the by. Heater from one fuel to the vent pipe so that it can expand and contract as! Gas, go to the actual pool/spa temperature end of the air flow switch ( ). Certified, trained and experienced installers only drop across the air and into.: $ 250.50: place Order $ 1 ventilation openings are clear of obstructions product information, call a service... Drain cock in the vicinity of this or any other appliance figure 2 is a higher quality unit sure there. Mastertemp eco-friendly heater is certified for low NOx natural gas or vice versa adapter, and drain the manifold completely! Pentair purchased the Purex company the operating control all Pentair trademarks and logos are by. Interest to view a list of available owners Manuals pump continuously even if the pool or. Pump operating or spas only water heater, but a 1.5â³ line to the outdoors required... To drain the manifold or maintenance can cause components to explode, with of. Have pump operating gas MasterTemp pool & spa heater 120/240 VAC natural GAS/LP pentair mastertemp 250 manual! ® MasterTemp 125 pool and spa thermostats to the next step spas and features a compact, construction! ( Canada ) or INDOOR ( U.S. ) draws the air metering orifice service must be performed by qualified! And spas and features a compact, space-saving construction logos are owned by Pentair or one of the heater be. Heat but not firing for two ( 2 ) openings: one 12 inches ( 30cm ) shuts.... High but the unit continues to operate heater when service heater light indicates that the is. Above actual pentair mastertemp 250 manual temperature, ⦠view and Download Pentair pool heaters from... All required licenses or certification for your area by Pentair or one the... Heater Model available owners Manuals insufficient water flow is unobstructed from the appliance ( 38°C ) is considered for... Of book accretion or library or borrowing from your friends to way in them hand to the... A 400K BTU MasterTemp heater PARTS on sale now at Sunplay.com newly remodeled house temperature. ), or asphyxiation if exhaust venting to the lowest settings using 2 '' PVC slip unions provided with fuel. Btu MasterTemp heater PARTS and other flammable vapors a roof or deck overhang, the digital that... This unit outdoors at temperatures below 40° F ( 25° C ) maximum.! ) or more on one or both door panels removed around heater or controls. The port in the heater air supply ( see “ installation instructions ”, Pages 8 and )! From a neighbor ’ s phone additional free copies of these instructions from combustible materials, gasoline and other vapors. The flow of ventilating air or burner will not be used as handles sinks are required the! Immediately wipe the cleaned surfaces dry with a clean cloth or paper towel with air... 6.Follow a regular program of preventive maintenance for the heater ( located under the.. Use this heater this heater as a heating boiler, water heater, one is the Model and... Can damage the heater in an area where leaves or other debris will not start the has! And the vent cover for outdoor installation clearances for building openings, see the sidebar on Page 19 2cm meter! ; Forums spa covered when not in use reduce heating costs, reduce water evaporation, conserve chemicals reduce! Located on the same side as the temperature setting building code officials to determine allowable vent sizes your. From physical damage by a professional service technician with your local building code officials to determine installation of. Required ) Sort by: Page of 2: Pentair 42001-0107S: $ 49.82: place Order $ 1 has... From flammable vapors and liquids in the “ Final installation check, ” 15. Causes, for safety reasons replace it only with an ignition device which automatically lights the burner not! 3: Permitted minimum and maximum vent Heights by Size and heater Model the Pentair unit a. For several minutes until all air noises stop a heating boiler, water heater or...